Best 4/0 SER Cable for Service Entrance
The following guide highlights top 4/0 SER cables commonly used to deliver power from the service drop to the meter base and from the meter base to the distribution panel. These aluminum service entrance cables are selected for typical residential and small commercial installations, offering multiple 4/0 conductors with a 2/0 grounding conductor. Use this overview to compare lengths, construction, and grounding capabilities across reputable brands.
| Product | Brand | Length | Conductor Set | Ground |
|---|---|---|---|---|
| Nassau Electrical Supply 50′ 4/0-4/0-4/0-2/0 SER | Nassau Electrical Supply | 50 ft | Three 4/0 AWG, One 2/0 AWG | 2/0 |
| Wirenco 20FT Cut 4/0-4/0-4/0-2/0 SER | Wirenco | 20 ft | Three 4/0 AWG | 2/0 |
| Wirenco 15FT Cut 4/0-4/0-4/0-2/0 SER | Wirenco | 15 ft | Three 4/0 AWG | 2/0 |
| NASSAU 25′ SER Cable | Nassau Electrical Supply | 25 ft | Three 4/0 AWG | 2/0 |
| NASSAU 50′ 4/0-4/0-2/0-4 Al Mobile Home Feeder | Nassau Electrical Supply | 50 ft | Two 4/0, One 2/0, One 4 | 4 AWG |
Note: Specifications such as conductor material (aluminum), voltage rating (600V), and construction are typical for SER cables used in service entrance and feeder applications. Always verify local code requirements and consult a licensed electrician for compliant installations.
Nassau Electrical Supply 50′ SER Cable

Product features include three 4/0 AWG conductors with a 2/0 grounding conductor, all aluminum construction suitable for 600V service. The package is designed to support typical residential service drops and main panel feeders, with robust connectors and insulation optimized for outdoor use.
NASSAU 25′ SER Cable

This Nassau offering follows standard SER configurations with three 4/0 conductors and a 2/0 grounding conductor, designed for secure service entrance applications. Length options provide flexibility for shorter runs from the service drop to the meter or panel location.
NASSAU 50′ Mobile Home Feeder Cable

This cable is configured as a 4/0-4/0-2/0-4 construction, intended for mobile home feeder installations. Grounding conductor size is listed as 4 AWG, with an amperage rating suitable for 200-amp service in many setups. Polymer insulation and outdoor-rated jacket are common features.
Wirenco 20FT Cut 4/0-4/0-4/0-2/0 SER Cable

Wirenco’s 20-foot SER cable is designed to deliver power from the service drop to the meter base and onward to the distribution panel. It features three 4/0 AWG conductors with a 2/0 grounding conductor and an outside diameter of approximately 1.496 inches, suitable for tight interior or exterior runs where space is constrained.
Wirenco 15FT Cut 4/0-4/0-4/0-2/0 SER Cable

This 15-foot Wirenco SER cable provides a compact option for shorter service runs. It maintains three 4/0 AWG conductors with a 2/0 grounding conductor, optimized for efficient installation from the service drop to the meter base and distribution panel.
Buying Guide
- Conductor configuration: Look for three 4/0 AWG conductors with a 2/0 grounding conductor; ensure the cable is rated for 600V or higher depending on your system.
- Material and jacket: Aluminum conductors with rugged insulation are common for SER cables used in outdoor and direct-burial settings; verify outdoor rating and UV resistance if exposed.
- Length and routing: Choose lengths that minimize splices and maximize straight runs from service entrance to panel. Longer runs may require specialized fittings or clamps.
- Code compliance: SER cables must comply with local electrical codes and utility requirements. Confirm gauge and grounding conductor sizing for service size and capacity.
- Installation considerations: Ensure proper strain relief, protection from physical damage, and adherence to conduit or trenching guidelines as applicable.
- Grounding and bonding: The 2/0 grounding conductor size and method of grounding should align with system grounding requirements and local regulations.
- Brand reputation and documentation: Favor reputable brands with clear product specifications and compatibility notes for service equipment, meters, and panels.